TUBELESS v0.4.8

Observe and supply step outputs

Pass outputObserver in a pipeline’s run controls to capture raw step results through your own encoder and writer. Tubeless awaits the write before publishing the validated value and starting dependent steps. The executable recipe captures text while its output schema publishes a character count.

import { v8StepCacheCodec } from "tubeless/node";

const run = await pipeline.run(options, {
  outputObserver: {
    encode: v8StepCacheCodec.encode,
    async write(record, { signal }) {
      await outputStore.save(record, { signal });
    },
  },
});

pipeline and outputStore are application-owned. The Node codec is optional; other runtimes supply their own lossless encoder. There is no default output store, encoding, retention policy, or CLI flag. Hosts can decode their saved raw values and supply them to a later invocation with suppliedOutputs. For a full failure/restart example, use the host recovery recipe.

Encode first, write after validation

The observer has two callbacks:

  • encode(value, { signal }) receives the raw handler result as unknown, before outputSchema transforms or mutates it. Return a lossless Uint8Array snapshot without mutating the value. Core copies the bytes before validation. Encoding may run even when validation later rejects the result; do not record successful completion in this callback.
  • write(record, { signal }) receives the detached encoded bytes after output validation and any normal cache write succeed. Resolve after your persistence acknowledges the write. The record includes pipelineId, stepId, runId, optional attemptId, definitionIdentity, origin, and encodedValue.

A string-input output schema can publish a number. The saved bytes represent the string, so a host can later decode the same schema input. Saving the published number would lose that property. Encoders must preserve supported values such as undefined and reject unsupported values rather than silently change their shape. The optional V8 codec rejects lossy round trips; see cache codecs.

The observer belongs to this invocation and its methods are captured when the run starts. Independent steps can encode and write concurrently, bounded by the run’s maxConcurrency; a step holds its slot through persistence. A sink that needs serial writes must serialize them itself. Treat callback values and metadata as read-only; ownership of each encoded byte buffer transfers to the writer.

Which outputs are captured

Output Behavior
Successful handler Encode its raw result, then write with origin handler
Cache hit Encode the decoded raw value, then write with origin cache
Policy skip Encode the skip value, including undefined, then write with origin policy
Structural skip or failed handler No observer call
Failed output validation or cache write Encoding may have happened; no output write
Dry run No observer calls, including for preview handlers and policy skips
Supplied output or test override Validate normally; no encoding or output write
Finalizer and result schema Outside this step boundary

Policy skips without output schemas need no execution attempt; their records omit attemptId. Child pipelines, remote steps, fan-out, and iteration are captured as whole wrapper outputs. The observer is never inherited into child runs. Authored PipelineChildRunControls reject both outputObserver and suppliedOutputs; invoke a pipeline’s run separately to configure its own recovery.

plan({ outputObserver }) validates the callback shape but calls neither method. Observers do not select steps, change definition identity, or place values in plans, step hooks, traces, reports, or Studio. Protect output storage as application data. Host callbacks and their error messages must apply your redaction policy. The final pipeline result remains available through the usual result hooks.

Supply saved raw values

Pass a ReadonlyMap from this pipeline’s step IDs to resolved raw values:

const suppliedOutputs = new Map<"load", unknown>([
  ["load", await codec.decode(savedRecord.encodedValue)],
]);
const run = await pipeline.run(options, {
  stepIds: ["load", "summarize"],
  suppliedOutputs,
});

The host checks the record’s business execution, pipeline, step, definition, explicit implementation version, input, and codec compatibility before reuse. Graph equality alone cannot establish compatibility. An omitted implementation version means compatibility is unknown. Supply asserts that the step’s effect already happened; Tubeless does not check that assertion or retrieve records.

Supplied values remain unknown until outputSchema validates and transforms them. Supply the raw schema input, such as the saved string rather than its published number. Without a schema, the host owns the type assertion. A map entry containing undefined is present; it differs from an absent entry. Functions are values, not factories, and promises/thenables are invalid.

Entries are copied at admission, but domain values are not cloned. Decode fresh objects for each invocation: schemas may mutate them, and active runs must not share or externally modify mutable restored values. Domain options still validate on every invocation, including a fully supplied run.

Supply never selects steps or prunes target prerequisites. Unfiltered runs still execute every step; target selection retains its full required closure. To omit upstream I/O behind a supplied intermediate, use exact stepIds including that intermediate and its consumers. Unknown IDs and supplies for unselected steps fail planning before any handler or observer runs.

Selected supplied steps bypass their handler, skip predicate, dry-run handler, required-input checks, failure gates, child/remote dispatch, and cache I/O. They validate when scheduled, then publish normally. Fail-fast or external cancellation can prevent an unstarted supplied step from completing. continueOnError permits supplied committed work beyond a failed prerequisite, while the run retains its errors. Dry runs may reuse supplies, but never call observers. Supplies are not encoded or written again when an observer is also configured.

plan({ suppliedOutputs, stepIds }) accounts for supplied steps and their consumers without invoking schemas or including values. A successful plan cannot promise that a supplied value will validate. Reports, lifecycle events, traces, stored history, and nested progress carry outputSource: "supplied" even when validation fails or is cancelled. Reporters and Studio label these steps (supplied); those metadata channels do not contain the supplied value. The finalized result follows the ordinary result contract.

Failures and uncertain writes

Invalid observer or supply controls fail planning with TUBELESS_RUN_OUTPUT_RECOVERY_INVALID. Encoder/writer failure or invalid encoded bytes fail the step with TUBELESS_STEP_OUTPUT_OBSERVATION_FAILED, phase execution, kind step. Required dependents remain blocked. Fail-fast stops new dispatch and drains active work; continueOnError allows independent branches. runOrThrow throws PipelineExecutionError for an unsuccessful run. Nonempty test overrides cannot be combined with either recovery control; ordinary test runs can exercise host persistence and supply.

Both callbacks receive the run signal. Cancellation checks surround capture and writing, and the run waits for started callbacks to settle. A write may commit before cancellation or a lost acknowledgement: its saved record may remain valid even when the step reports cancellation. The host must reconcile uncertain writes.

Output capture does not make external effects exactly once. A process can die after an effect but before recording its result. Use business idempotency keys or reconcile the effect before retrying. A graph fingerprint does not establish code compatibility; hosts deciding reuse also need explicit implementation, business execution, input, and codec identity. Missing implementation versions mean compatibility is unknown. The host recovery guide shows fresh-instance recovery and the crash-before-acknowledgement case.