# Observe and supply step outputs

Pass `outputObserver` in a pipeline's run controls to capture raw step results
through your own encoder and writer. Tubeless awaits the write before publishing
the validated value and starting dependent steps. The
[executable recipe](https://github.com/chetmancini/tubeless/blob/main/examples/step-output-observation.ts) captures text while
its output schema publishes a character count.

```ts
import { v8StepCacheCodec } from "tubeless/node";

const run = await pipeline.run(options, {
  outputObserver: {
    encode: v8StepCacheCodec.encode,
    async write(record, { signal }) {
      await outputStore.save(record, { signal });
    },
  },
});
```

`pipeline` and `outputStore` are application-owned. The Node codec is optional;
other runtimes supply their own lossless encoder. There is no default output
store, encoding, retention policy, or CLI flag. Hosts can decode their saved raw
values and supply them to a later invocation with `suppliedOutputs`. For a full
failure/restart example, use the [host recovery recipe](https://tubeless.io/docs/step-output-recovery.md).

## Encode first, write after validation

The observer has two callbacks:

- `encode(value, { signal })` receives the raw handler result as `unknown`,
  before `outputSchema` transforms or mutates it. Return a lossless `Uint8Array`
  snapshot without mutating the value. Core copies the bytes before validation.
  Encoding may run even when validation later rejects the result; do not record
  successful completion in this callback.
- `write(record, { signal })` receives the detached encoded bytes after output
  validation and any normal cache write succeed. Resolve after your persistence
  acknowledges the write. The record includes `pipelineId`, `stepId`, `runId`,
  optional `attemptId`, `definitionIdentity`, `origin`, and `encodedValue`.

A string-input output schema can publish a number. The saved bytes represent the
string, so a host can later decode the same schema input. Saving the published
number would lose that property. Encoders must preserve supported values such as
`undefined` and reject unsupported values rather than silently change their shape.
The optional V8 codec rejects lossy round trips; see [cache codecs](https://tubeless.io/docs/step-output-cache.md#custom-stores-and-codecs).

The observer belongs to this invocation and its methods are captured when the
run starts. Independent steps can encode and write concurrently, bounded by the
run's `maxConcurrency`; a step holds its slot through persistence. A sink that
needs serial writes must serialize them itself. Treat callback values and metadata
as read-only; ownership of each encoded byte buffer transfers to the writer.

## Which outputs are captured

| Output                                  | Behavior                                                                      |
| --------------------------------------- | ----------------------------------------------------------------------------- |
| Successful handler                      | Encode its raw result, then write with origin `handler`                       |
| Cache hit                               | Encode the decoded raw value, then write with origin `cache`                  |
| Policy skip                             | Encode the skip value, including `undefined`, then write with origin `policy` |
| Structural skip or failed handler       | No observer call                                                              |
| Failed output validation or cache write | Encoding may have happened; no output write                                   |
| Dry run                                 | No observer calls, including for preview handlers and policy skips            |
| Supplied output or test override        | Validate normally; no encoding or output write                                |
| Finalizer and result schema             | Outside this step boundary                                                    |

Policy skips without output schemas need no execution attempt; their records
omit `attemptId`. Child pipelines, remote steps, fan-out, and iteration are
captured as whole wrapper outputs. The observer is never inherited into child
runs. Authored `PipelineChildRunControls` reject both `outputObserver` and
`suppliedOutputs`; invoke a pipeline's `run` separately to configure its own recovery.

`plan({ outputObserver })` validates the callback shape but calls neither method.
Observers do not select steps, change definition identity, or place values in
plans, step hooks, traces, reports, or Studio. Protect output storage as application
data. Host callbacks and their error messages must apply your redaction policy.
The final pipeline result remains available through the usual result hooks.

## Supply saved raw values

Pass a `ReadonlyMap` from this pipeline's step IDs to resolved raw values:

```ts
const suppliedOutputs = new Map<"load", unknown>([
  ["load", await codec.decode(savedRecord.encodedValue)],
]);
const run = await pipeline.run(options, {
  stepIds: ["load", "summarize"],
  suppliedOutputs,
});
```

The host checks the record's business execution, pipeline, step, definition,
explicit implementation version, input, and codec compatibility before reuse.
Graph equality alone cannot establish compatibility. An omitted implementation
version means compatibility is unknown. Supply asserts that the step's effect
already happened; Tubeless does not check that assertion or retrieve records.

Supplied values remain `unknown` until `outputSchema` validates and transforms
them. Supply the raw schema input, such as the saved string rather than its
published number. Without a schema, the host owns the type assertion. A map entry
containing `undefined` is present; it differs from an absent entry. Functions are
values, not factories, and promises/thenables are invalid.

Entries are copied at admission, but domain values are not cloned. Decode fresh
objects for each invocation: schemas may mutate them, and active runs must not
share or externally modify mutable restored values. Domain options still validate
on every invocation, including a fully supplied run.

Supply never selects steps or prunes target prerequisites. Unfiltered runs still
execute every step; target selection retains its full required closure. To omit
upstream I/O behind a supplied intermediate, use exact `stepIds` including that
intermediate and its consumers. Unknown IDs and supplies for unselected steps fail
planning before any handler or observer runs.

Selected supplied steps bypass their handler, skip predicate, dry-run handler,
required-input checks, failure gates, child/remote dispatch, and cache I/O. They
validate when scheduled, then publish normally. Fail-fast or external cancellation
can prevent an unstarted supplied step from completing. `continueOnError` permits
supplied committed work beyond a failed prerequisite, while the run retains its
errors. Dry runs may reuse supplies, but never call observers. Supplies are not
encoded or written again when an observer is also configured.

`plan({ suppliedOutputs, stepIds })` accounts for supplied steps and their
consumers without invoking schemas or including values. A successful plan cannot
promise that a supplied value will validate. Reports, lifecycle events, traces,
stored history, and nested progress carry `outputSource: "supplied"` even when
validation fails or is cancelled. Reporters and Studio label these steps
`(supplied)`; those metadata channels do not contain the supplied value. The
finalized result follows the ordinary result contract.

## Failures and uncertain writes

Invalid observer or supply controls fail planning with
`TUBELESS_RUN_OUTPUT_RECOVERY_INVALID`. Encoder/writer failure or invalid encoded
bytes fail the step with `TUBELESS_STEP_OUTPUT_OBSERVATION_FAILED`, phase
`execution`, kind `step`. Required dependents remain blocked. Fail-fast stops new
dispatch and drains active work; `continueOnError` allows independent branches.
`runOrThrow` throws `PipelineExecutionError` for an unsuccessful run. Nonempty
test overrides cannot be combined with either recovery control; ordinary test
runs can exercise host persistence and supply.

Both callbacks receive the run signal. Cancellation checks surround capture and
writing, and the run waits for started callbacks to settle. A write may commit
before cancellation or a lost acknowledgement: its saved record may remain valid
even when the step reports cancellation. The host must reconcile uncertain writes.

Output capture does not make external effects exactly once. A process can die
after an effect but before recording its result. Use business idempotency keys or
reconcile the effect before retrying. A graph fingerprint does not establish code
compatibility; hosts deciding reuse also need explicit implementation,
business execution, input, and codec identity. Missing implementation versions
mean compatibility is unknown. The [host recovery guide](https://tubeless.io/docs/step-output-recovery.md)
shows fresh-instance recovery and the crash-before-acknowledgement case.